Skip to content

Lucideon - Supporting Best Practice in Color Measurement

 

Ensuring uniformity in color across the paint and coatings sector around the world is a critical issue, and one that requires absolute precision accuracy

In this article, Lucideon's Sean Hillman gives some insight on how this is achieved, and sets out the parameters to ensure best practice in color measurement.

Within the paint and coatings sector, it goes without saying that a customer in one part of the world will expect the same shade in another.

And in international trade, proof of compliance with such standards is not only a good indicator that a company is supplying merchandise of the required quality, but what customers would expect from an industry based on color, as well as surface protection.

Colour Standards

 

The first steps in colour precision

To achieve color accuracy, color measurement instruments are relied on throughout the sector to record values accurately, no matter where they are, and measure any differences precisely.

These instruments provide numerical values of color, for use in computer programmes, which in turn calculate the changes needed in production processes to ensure products from different factories create the same, uniform color.

However, the issue arises on how this process is mentioned and quality assured throughout the process.

It's imperative that the instruments work correctly. If they do not, then costly mistakes can be made during production.

So, while a good quality instrument is an important first step, a maintenance programme is absolutely vital to keep it working correctly, but event then, this still does not ensure that users are getting consistent answers.

 

Colour Standards - the vital link

To achieve consistent color, a set of Colour Standards that allows checks on the performance of the instrument from day to day, week to week and month to month are key in ensuring that technology is working consistently.

Much like weights, there needs to be a defining guide, and standard to follow.

Since the 1960s, Lucideon has developed stable standards for use with color measurement instruments and supplies them to all industries where the measurement of color is important, including paint and coatings manufacturers worldwide.

They are particularly useful for those that trade internationally, where color measurement has to be shown to be correct so that supplier and buyer can be sure that products are tested to agreed standards.

The Lucideon Colour Standards comprise of 12 glazed ceramic tile standards, which provide a direct check on colour difference measurement for repeatability purposes.

The series comprises of three neutral greys for checking photometric linearity, seven chromatic standards for checking spectral response, and two color difference standards.

Most users measure the Set of 12 Colour Standards every week or every month and record the results.

If the results change then there is something wrong with the spectrophotometer.

With the Colour Standards maintaining stability of 20-plus years, this offers a more agile and appropriate approach than waiting for the annual service to find any problems with a spectrophotometer.

Using the measurements from the Colour Standards is also beneficial for determining when a spectrophotometer needs servicing, and they also allow the performance and accuracy of instruments at widely separated locations to be compared, ensuring that the colors can be communicated accurately and repeatably, a process that improves inter-laboratory alignment.

Customized Colour Standards can also be developed for specific colors that might be required by suppliers of components into their supply chain, to match their products too. This ensures color consistency throughout the manufacturing processes.

And as a UKAS-Accredited Calibration Laboratory, Traceable Reflectance and Colorimetric Values can also be used to calibrate Lucideon's Colour Standards, with traceability to the National Physical Laboratory at Teddington, UK.

 

Color counts in space

The significance of a standard approach to color is not just confined to international boundaries.

Colour Standards developed by Lucideon are currently helping to ensure that the colors captured by the Perseverance mission to Mars are recorded to pinpoint accuracy.

The swatches, made by Lucideon in the UK, were purchased by the Niels Bohr Institute and, in their clean-rooms, placed on a set of calibration devices to support the Mastcam-Z camera system on the Perseverance rover.

For the Mars mission the Colour Standards have been developed to set the cameras to, with the calibration devices being used by scientists to fine-tune the signals received from the cameras, which have been engineered to zoom in, focus and take 3D pictures and video at high speed to allow detailed examination of both close and distant objects on the planet.

The illumination of the sun through the dusty atmosphere on Mars can affect the colors and it's important that the equipment can be calibrated against standard swatches for absolute accuracy.

 

» Further information on Colour Standards

 